Appendix H - EMV Settings (EMV Only)
DynaPro Go| Handheld PIN Pad Device with MSR/Contact/Contactless | Programmer’s Manual (COMMANDS)
Page 179 of 247 (
D998200136-31
)
Table 4-116 - EMV Contact Application Settings Slot 2
Tag Description
Tag
Configurable
Default Value (Hex)
Application DF Name
84
MagTek
A0 00 00 00 03 20 10
TDOL
97
MagTek
5F2403
Acquirer ID
9F01
MagTek
00 00 00 00 00 01
Application AID
9F06
MagTek
A0 00 00 00 03 20 10
Floor Limit
9F1B
MagTek
00 00 27 10
DDOL
9F49
MagTek
9F 37 04 5A 08 5F 34 01 9A 03
ASI (Application Select
Indicator)
DFDF23
MagTek
01
Application Version
9F09
MagTek
00 8C
TAC - Default
DFDF70
MagTek
00 00 00 00 00
TAC - Denial
DFDF71
MagTek
00 00 00 00 00
TAC - Online
DFDF72
MagTek
00 40 00 00 00
Payment Brand Account
Type
DFDF73
MagTek
03
Terminal Threshold Value DFDF10
MagTek
00 00 00 00 40 00
Terminal Target
Percentage
DFDF11
MagTek
32
Terminal Max Target
Percentage
DFDF12
MagTek
46