4 - Command Set
DynaPro Go| Handheld PIN Pad Device with MSR/Contact/Contactless | Programmer’s Manual (COMMANDS)
Page 57 of 247 (
D998200136-31
)
4.3.10
Command 0x0A - Request MSR Data
This command directs the device to send MSR data to the host; it should be issued after a
command has successfully completed.
If an error occurs, the device terminates the command and reports the error in ACKSTS of
. For a full list of error codes, see
If no error occurs, the device sends multiple instances of
Report 0x23 - Card Data Report
no MSR data is available, the device sends a single
Report 0x23 - Card Data Report
Length of 0.
Table 4-11 - Usage Table for Command 0x0A
Bit
7
6
5
4
3
2
1
0
Byte 0
0x0A
Byte 1
0x00