Page 4
©
2020 Sensata Technologies
Introduction
10
11
9
8
13
12
Figure 1-2, Electrical Connection Points
DC
Equipment
Ground
Terminal
AC Entry/
Exit
Connections
Intake Air Vents
(and on right side – front)
Positive (+)
DC terminal
(under cover)
Negative (–)
DC terminal
(under cover)
Mounting
Flange
8
DC Equipment Ground Terminal
– this connection is used to tie the exposed chassis
of the inverter to the DC grounding system. This terminal accepts CU/AL conductors from
#14 to #2 AWG (2.1 to 33.6 mm
2
).
9
AC Entry/Exit Connections
– two 3/4” knockouts provided with cable-clamp strain
reliefs to accommodate and secure the AC input and output
fi
eld wiring.
10
Intake Air Vents
–
ventilation openings to pull in air to help keep the inverter cool for
peak performance. The intake air vents are located on the front side and at the front on
the right side; also see Figure 2-3 for the location of the air vents.
11
Positive DC Terminal
– provides a 360 degree connection point for the positive (+) cable
from the battery bank; consists of a 5/16-18 bolt with a Kep or Flange nut that holds the
battery cable to the DC terminal.
12
Negative DC Terminal
– provides a 360 degree connection point for the negative (-)
cable from the battery bank; consists of a 5/16-18 bolt with a Kep or Flange nut that
holds the battery cable to the DC terminal.
13
Mounting Flange
– used to secure the inverter to a shelf or wall.