Page 30
©
2020 Sensata Technologies
Installation
2.9 Final
Inspection
1. Verify all cables are secured with wire ties or other non-conductive fasteners to prevent cha
fi
ng
or damage from movement and vibration.
2. Verify strain reliefs or grommets are in place to prevent damage to the wiring where it passes
through walls, bulkheads, or other openings.
3. Verify all AC connections are correct and torqued to a maximum of 16 in lbf (1.8 N-m).
4. Replace the covers on the main electrical/distribution panel.
5. Replace the chassis access cover.
6. Verify the inverter’s front panel switch is in the “OFF” position.
Information on the RV-C plug/connector:
• Plug (4-pin) – PN: 39-01-2040 (Molex 5557 Series)
• Crimp-on connectors (female) – PN: 39-00-0039 (Molex 5556 Series)
• Input voltage: 8 VDC – 17 VDC
• Input amperage: 40mA typical, 60 mA Max @12V
• Operating Temperature Range: -20 to 60 Deg C
Figure 2-18, RV-C Connector/Plug Designation
3
4
2
1
RV-C Plug
(cable end)
4
3
2
1
RV-C
Connector
(on inverter)
Pin
Designation
1
CAN_H
2
CAN_L
3
PS–
4
PS+
Figure 2-17, RV-C Connections (Two Inverters with Accessories)
Magnum Inverter/Charger (INV 1) Magnum Inverter/Charger (INV 2)
ME-AGS-N
ME-BMK
Network Bus/
Backbone In RV
RV-C
compliant
device
RV-C
compliant
device
T
T
Te
rm
in
a
to
r
Te
rm
in
a
to
r