Operation
3.3 Current
Flow
The following
fi
gures show the current
fl
ow in the MSH3012RV during different modes:
Figure 3-7, MSH3012RV Current Flow – Charger Back-off
MSH Inverter
DC Current
(Battery)
0A
AC Loads
(Medium)
+20A
AC Current
(Grid/Gen)
-20A
Charger Back-off
– When the AC loads increase, the MSH3012RV inverter reduces or stops the
battery charge current to allow the grid/generator to continue powering the AC loads.
Figure 3-6, MSH3012RV Current Flow – Charging and AC Pass-thru
Charging and AC Pass-thru
– The MSH3012RV inverter uses current from the grid/generator
to power the AC loads, and also converts this current to charge the battery.
MSH Inverter
DC Current
(Battery)
+10A
AC Loads
(Small)
+10A
AC Current
(Grid/Gen)
-20A
Figure 3-5, MSH3012RV Current Flow – Inverting
Inverting
– The MSH3012RV inverter converts the current from the battery to power the AC loads.
MSH Inverter
AC Current
(Grid/Gen)
0A
AC Loads
(Small)
+10A
DC Current
(Battery)
-10A