background image

   

Industrial

 

Electronic Devices 

 

 

 ADFweb.com Srl – IT31010 – Mareno – Treviso                                                      INFO:  

www.adfweb.com

      Phone +39.0438.30.91.31            

 

User Manual   

OPC UA Server / BACnet Master 

 

Document code: MN67B31_ENG     Revision 1.000    Page 1 of 30

 

 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

 

 
 
 
 
 

 

 
 
 

User Manual 

Revision 1.000 
English 

 

OPC UA Server / BACnet  Master - 
Converter

 

 

(Order Code: HD67B31-B2) 

 

for Website information:  

http://www.adfweb.com/?Product=HD67B31

    

 

for Price information: 

http://www.adfweb.com/?Price=HD67B31-B2

  

 
 

Benefits and Main Features: 

 

Triple electrical isolation 

 

Power Supply 18…35V DC and 8…24 V AC 

 

Temperature range: -40°C/+85°C (-40°F/+185°F) 

For others OPC UA Server devices, see also the following links:  

 
OPC UA Server from/to …

 

www.adfweb.com?Product=HD67B26

  

(

Serial

www.adfweb.com?Product=HD67B27

  

(

Modbus Master

www.adfweb.com?Product=HD67B28

  

(

Modbus Slave

www.adfweb.com?Product=HD67B29

  

(

Modbus TCP Master

www.adfweb.com?Product=HD67B30

 

(

Modbus TCP Slave

www.adfweb.com?Product=HD67B32

 

(

Bacnet Slave

www.adfweb.com?Product=HD67B33

  

(

CAN

www.adfweb.com?Product=HD67B34

  

(

CANopen

www.adfweb.com?Product=HD67B35

  

(

DeviceNet Master

www.adfweb.com?Product=HD67B36

  

(

DeviceNet Slave

www.adfweb.com?Product=HD67B37

  

(

DMX

www.adfweb.com?Product=HD67B38

  

(

EtherNet/IP Master

www.adfweb.com?Product=HD67B39

  

(

EtherNet/IP Slave

www.adfweb.com?Product=HD67B40

  

(

J1939

www.adfweb.com?Product=HD67B41

  

(

KNX

www.adfweb.com?Product=HD67B42

    

(

MQTT

www.adfweb.com?Product=HD67B43

    

(

NMEA0183

www.adfweb.com?Product=HD67B44

    

(

NMEA2000

www.adfweb.com?Product=HD67B45

    

(

PROFINET Master

www.adfweb.com?Product=HD67B46

    

(

PROFINET Slave

www.adfweb.com?Product=HD67B47

  

(

SNMP Manager

www.adfweb.com?Product=HD67B48

  

(

SNMP Agent

 
Do you have an your customer protocol? 

See the following links: 

www.adfweb.com?Product=HD67003

 

Do you need to choose a device? do you want help? 

Ask it to the following link: 

www.adfweb.com?Cmd=helpme

 

 

User Manual 

Summary of Contents for HD67B31 Series

Page 1: ...29 Modbus TCP Master www adfweb com Product HD67B30 Modbus TCP Slave www adfweb com Product HD67B32 Bacnet Slave www adfweb com Product HD67B33 CAN www adfweb com Product HD67B34 CANopen www adfweb com Product HD67B35 DeviceNet Master www adfweb com Product HD67B36 DeviceNet Slave www adfweb com Product HD67B37 DMX www adfweb com Product HD67B38 EtherNet IP Master www adfweb com Product HD67B39 Et...

Page 2: ...29 WARRANTIES AND TECHNICAL SUPPORT 30 RETURN POLICY 30 Pagina 2 di 30 UPDATED DOCUMENTATION Dear customer we thank you for your attention and we remind you that you need to check that the following document is Updated Related to the product you own To obtain the most recently updated document note the document code that appears at the top right hand corner of each page of this document With this ...

Page 3: ...locks etc QUALIFIED PERSONNEL The device can be used only by qualified personnel strictly in accordance with the specifications Qualified personnel are persons who are familiar with the installation assembly commissioning and operation of this equipment and who have appropriate qualifications for their job RESIDUAL RISKS The device is state of the art and is safe The instruments can represent a po...

Page 4: ...lectronic Devices ADFweb com Srl IT31010 Mareno Treviso INFO www adfweb com Phone 39 0438 30 91 31 User Manual OPC UA Server BACnet Master Document code MN67B31_ENG Revision 1 000 Page 4 of 30 EXAMPLE OF CONNECTION ...

Page 5: ...web com Srl IT31010 Mareno Treviso INFO www adfweb com Phone 39 0438 30 91 31 User Manual OPC UA Server BACnet Master Document code MN67B31_ENG Revision 1 000 Page 5 of 30 CONNECTION SCHEME Figure 1a Connection scheme for HD67B31 IP B2 ...

Page 6: ...ices ADFweb com Srl IT31010 Mareno Treviso INFO www adfweb com Phone 39 0438 30 91 31 User Manual OPC UA Server BACnet Master Document code MN67B31_ENG Revision 1 000 Page 6 of 30 Figure 1b Connection scheme for HD67B31 MSTP B2 ...

Page 7: ...ster converter It allows the following characteristics Up to 1500 bytes in reading and 1500 bytes in writing Two directional information between BACnet and OPC UA Mountable on 35mm Rail DIN Wide power supply input range 8 24V AC or 12 35V DC Wide temperature range 40 C 85 C 40 F 185 F CONFIGURATION You need Compositor SW67B31 software on your PC in order to perform the following Define the paramet...

Page 8: ... BACnet Master Document code MN67B31_ENG Revision 1 000 Page 8 of 30 POWER SUPPLY The devices can be powered between a wide range of tensions For more details see the two tables below VAC VDC Vmin Vmax Vmin Vmax HD67B31 B2 8V 24V 12V 35V Consumption at 24V DC Device W VA HD67B31 B2 4 Caution Not reverse the polarity power HD67B31 xxx B2 ...

Page 9: ...e device has got two functions mode depending of the position of the Dip1 of Dip Switch A The first with Dip1 in Off position factory setting is used for the normal working of the device The second with Dip1 in On position is used for upload the Project Firmware For the operations to follow for the updating see UPDATE DEVICE section According to the functioning mode the LEDs will have specifics fu...

Page 10: ...ks quickly Boot state Blinks very slowly 0 5Hz update in progress 2 BACnet comm yellow Flashing BACnet response OFF No BACnet response Blinks quickly Boot state Blinks very slowly 0 5Hz update in progress 3 OPC UA comm yellow Flashing OPC UA request OFF No OPC UA request Blinks quickly Boot state Blinks very slowly 0 5Hz update in progress 4 OPC UA error yellow ON An error has occurred OFF The dev...

Page 11: ...th a 120Ω resistor it is necessary to put ON dip 1 like in figure The maximum length of the cable should be 1200m 4000 feet Here some codes of cables Belden p n 8132 2x 28AWG stranded twisted pairs conductor foil shield braid shield Belden p n 82842 2x 24AWG stranded twisted pairs conductor foil shield braid shield Tasker p n C521 1x 24AWG twisted pair conductor foil shield braid shield Tasker p n...

Page 12: ...T The Ethernet connection must be made using Connector3 of HD67B31 xxx B2 with at least a Category 5E cable The maximum length of the cable should not exceed 100m The cable has to conform to the T568 norms relative to connections in cat 5 up to 100 Mbps To connect the device to an Hub Switch is recommended the use of a straight cable to connect the device to a PC PLC other is recommended the use o...

Page 13: ...ter use the available software that runs with Windows called SW67B31 It is downloadable on the site www adfweb com and its operation is described in this document This manual is referenced to the last version of the software present on our web site The software works with MSWindows XP Vista Seven 8 10 32 64bit When launching the SW67B31 the window below appears Fig 2 Note It is necessary to have i...

Page 14: ...contains the entire device s configuration A device s configuration can also be imported or exported To clone the configurations of a programmable OPC UA Server BACnet Master Converter in order to configure another device in the same manner it is necessary to maintain the folder and all its contents To clone a project in order to obtain a different version of the project it is sufficient to duplic...

Page 15: ...there is the possibility to change the language of the software and check the updatings for the compositor In the section Language it is possible to change the language of the software In the section Connection Options it is possible to check if there are some updatings of the software compositor in ADFweb com website Checking the option Check Software Update at Start of Program the SW67B31 check ...

Page 16: ...9 0438 30 91 31 User Manual OPC UA Server BACnet Master Document code MN67B31_ENG Revision 1 000 Page 16 of 30 In the section Software Settings it is possible to enable disable some keyboard s commands for an easier navigation inside the tables contained in the different sections of the software ...

Page 17: ...ON This section define the fundamental communication parameters of two buses OPC UA Server and BACnet Master By Pressing the Set Communication button from the main window for SW67B31 Fig 2 the window Set Communication appears Fig 3a The window is divided in three sections in order to define the different parameters of the converter OPC UA Server BACnet Master NTP Network Time Protocol Figure 3a Se...

Page 18: ...In the field Port the port of OPC UA Server is defined BACNET MASTER FOR BACNET IP This section is used to define the main parameters of BACnet IP line The means of the fields are the fields IP ADDRESS the IP address of BACnet IP side of the converter is defined In the fields SUBNET Mask the SubNet Mask of BACnet IP side of the converter is defined In the fields GATEWAY the default gateway of the ...

Page 19: ...In the field BACnet Device Name the name to give to the BACnet node is defined In the field MAC Address the MAC of BACnet node from 0 to 254 is defined The field Max Master specifies the highest allowable address for master nodes The value shall be less than or equal to 127 The field Max Info Frames specifies the maximum number of information frames the node may send before it must pass the token ...

Page 20: ...rs Fig 4 This section is used to define the list of OPC UA variables to read write The means of the checkboxes inside the table are In the field Type the data format of the OPC UA variable is defined In the field Position the starting byte of the internal memory arrays where getting the value is defined In the field Length the byte length of the OPC UA variable is defined In the field Name the nam...

Page 21: ...net slaves The means of the fields in the window BACnet in Read are the following In the field IP Address ID the IP address ID of the slave that contains the data to be read is defined In the field Object Type the object to be read is defined In the field Instance the instance number of the object is defined In the field Property the property to be read is defined In the field NByte the number of ...

Page 22: ... it is possible to insert an IP and port in this format 192 168 2 188 47808 In the field Poll Time the frequency of the request is defined in ms In the field Max Error the number of consecutive errors that the Master waits before resetting the data for the specific requests is defined In the field Position the starting byte of the internal memory array where mapping the data read is defined The fi...

Page 23: ...Byte the number of bytes of the BACnet object is defined By checking the field En Dest it is possible to enable the Destination Network D Net Destination Length D Len and Destination Address D Adr These informations are used for make a request to other segments of network through a BACnet router In the field D Net the destination network from 1 to 65535 is defined In the field D Len the length of ...

Page 24: ...e number of consecutive errors that the Master waits before stopping the specific requests is defined In the field Position the starting byte of the internal memory array from which taking the data to write is defined The field Start Bit is used for the Binary Output BACnet objects It is possible to select the bit in the byte from which taking the data In the field Mnemonic a description of the da...

Page 25: ...Turn ON the device Connect the Ethernet cable Insert the IP 192 168 2 205 Select which operations you want to do Press the Execute update firmware button to start the upload When all the operations are OK turn OFF the Device Put Dip1 of Dip Switch A in OFF position Turn ON the device If you know the actual IP address of the device you have to use this procedure Turn ON the Device with the Ethernet...

Page 26: ... PC Try to restart the PC Check the LAN settings If you are using the program inside a Virtual Machine try to use in the main Operating System If you are using Windows Seven Vista 8 or 10 make sure that you have the administrator privileges In case you have to program more than one device using the UDP Update you have to cancel the ARP table every time you connect a new device on Ethernet For do t...

Page 27: ...Srl IT31010 Mareno Treviso INFO www adfweb com Phone 39 0438 30 91 31 User Manual OPC UA Server BACnet Master Document code MN67B31_ENG Revision 1 000 Page 27 of 30 MECHANICAL DIMENSIONS Figure 8 Mechanical dimensions scheme for HD67B31 xxx B2 ...

Page 28: ...D67B31 xxx B 2 Connectors Type 2 Fixed Screw Terminal Enclosure Type B Modulbox 2M 35mm DIN Rail mounting BACnet Type IP BACnet IP MSTP BACnet MS TP Device Family HD67B31 OPC UA Server BACnet Master Converter Order Code HD67B31 IP B2 OPC UA Server BACnet IP Master Converter Order Code HD67B31 MSTP B2 OPC UA Server BACnet MS TP Master Converter ACCESSORIES Order Code AC34011 35mm Rail DIN Power Sup...

Page 29: ...ean countries with separate collection systems This symbol on the product or on its packaging indicates that this product may not be treated as household rubbish Instead it should be taken to an applicable collection point for the recycling of electrical and electronic equipment If the product is disposed correctly you will help prevent potential negative environmental factors and impact of human ...

Page 30: ...sh to exchange or repair it please do the following Obtain a Product Return Number PRN from our internet support at www adfweb com Together with the request you need to provide detailed information about the problem Send the product to the address provided with the PRN having prepaid the shipping costs shipment costs billed to us will not be accepted If the product is within the warranty of twelve...

Reviews: