Viewing Waveforms, Vectors, and Pictures
7-19
When the vector display is externally referenced, note that the burst vector does not lie along the 180º
line. You can rotate this display using the right knob or you can preset the rest position of the external
sync as follows:
1.
Press the
Config
button.
2.
If REFERENCE is not EXT, press the
Enter
button to select it.
3.
Select VECTOR and then press the
Enter
button.
4.
Select EXT PHASE PRESET and then turn the knob to preset the vector’s position using the
horizontal bar graphs.
When setting external phase preset, the knob will not scroll or spin the vector as it can do with the Vec.
Phase control. The external phase preset applies to both A: and B: inputs; there is not a separate preset
for each input.
NOTE:
The REFERENCE must set to EXT to adjust EXT PHASE PRESET.
Comparing Two Waveforms or Vectors (AVM-510A)
The AVM-510A has several ways to view and compare the signals at the A: and B: inputs. You can see
the waveforms of two composite signals together, either side-by-side or superimposed. You can
compare the waveforms of one composite and the Y (or G) channel of a component signal. You can
also display two composite vectors together (see Figures 7-21 to 7-23).
To view two waveforms at the same time, press the
Input
button once or twice until both the A and B
LEDs light. The label at the top left of the screen shows A and B.
Next to the Display button, the Alternate or Parade LED will be lit as follows:
•
Alternate
The two waveforms are on top of each other. The sweep rate can be 1H, 2H, or 2F.
The
Wfm Pos
button lets you choose which waveform to move vertically with the
V Pos
knob.
1 = A, 2 = B.
•
Parade
The two waveforms are side-by-side, with the A waveform on the left. The
Sweep
button does not let you change anything. The
Wfm Pos
button still lets you move the waveforms
separately. Note that if you try to push the
Display
button to switch from Alternate to Parade and
nothing happens, the problem is that the sweep rate is on 2F. Push the
Sweep
button and then
push the
Display
button.
You can compare a composite waveform from Input A: with the first channel (Y or G) of a component
waveform in this same way. If the graticules for these two systems are different, the graticule for the
composite waveform is used.
•
You cannot view two vectors and two waveforms at the same time. Pressing the
Vector
button a
second time displays the waveform and vector from the Input A:.
•
Line Select not available with two vectors (or with two waveforms).
•
Vector Phase operates on both vectors together.
•
Var. Gain works on both vectors (or both waveforms) together.
•
It is not possible to display a composite and a component vector together.
Содержание MM-410
Страница 16: ...About This Manual 1 4 Notes...
Страница 34: ...Installation 4 6 Notes...
Страница 48: ...Front Panel Operation 5 14 Notes...
Страница 102: ...Viewing Waveforms Vectors and Pictures 7 30 Notes...
Страница 126: ...Automatic Measurement AVM 510A 9 20 Notes...
Страница 139: ...AVM 510A Option T For Transmission Monitoring 11 5 Figure 11 3 Differential Gain Figure 11 4 Differential Phase...
Страница 148: ...AVM 510A C For Component Measurements 12 4 Notes...
Страница 158: ...Connector Pinouts B 4 Notes...
Страница 162: ...Calibration D 2 Notes...