47
/
48
Command
Description
FLA= / FLA=?
Command/Return format
Starting address of control flag area
FLA=
③
③
= Unsigned integer up to 8 digits
PRA= / PRA=?
Command/Return format
Starting address of setup parameter area
②
PRA=
③
③
= Unsigned integer up to 8 digits
MDA= / MDA=?
Command/Return format
Starting address of measurement data area
MDA=
③
③
= Unsigned integer up to 8 digits
FINSDNA= / FINSDNA=?
Command/Return format
FINS command parameter (DNA)
FINSDNA=
③
③
= 0: Own network
1 to 127: Destination network address
Note
Set this when using the FINS command.
FINSDA1= / FINSDA1=?
Command/Return format
FINS command parameter (DA1)
FINSDA1=
③
③
= 1 to 254
Note
Set this when using the FINS command (UDP).
FINSSA1= / FINSSA1=?
Command/Return format
FINS command parameter (SA1)
FINSSA1=
③
③
= 1 to 254
Note
Set this when using the FINS command (UDP).
CMUNITNO= / CMUNITNO=?
Command/Return format
C mode command parameter (unit number)
CMUNITNO=
③
③
= 0 to 31
Note
Set this when using the C mode command.