(4) PLC Link Setting screen
To apply the settings made on this screen, it is necessary to turn the power of the MG80-SC off and then on again.
①
Specifies the IP address and subnet mask of the MG80-SC. The format is a dot-delimited 4-digit format,
wherein each digit is in the range 0 to 255.
②
Specifies whether or not to use the PLC link. When this is selected, the PLC link is used.
③
Specifies the IP address and port number of the PLC to be connected when using the PLC link via Ethernet
connection.
④
Specifies the communication protocol to be used by the PLC link.
Check the available protocols for the PLC and select one of the following combinations:
PLC communication specifications
MG80-SC settings
PLC manufacturer Communication protocol
Protocol
Binary/ASCII
Connection
method
Mitsubishi
Electric
Corporation
MC protocol
1C frame format 4
1C Frame
ASCII
RS-232C
3C frame format 4
3C Frame
ASCII
RS-232C
1E frame
1E Frame
ASCII/Binary
TCP/UDP
3E frame
3E Frame
ASCII/Binary
TCP/UDP
3E frame (for iQ-R series)
3E Frame for iQ-R
ASCII/Binary
TCP/UDP
OMRON
Corporation
C-mode Commands
C mode command
ASCII
RS-232C
FINS Commands
FINS command
Binary
TCP/UDP
Keyence
Corporation
KV Host Link Mode
KV command
ASCII
RS-232C
Host-link
KV command
ASCII
TCP/UDP