CHAPTER 2: Overview/Design Guidelines
2.2 Design Guidelines, cont.
Eight Frame Cascade Limit
All inputs to the Mondo III are cascaded to subsequent frames via Cat5 cascade loop throughs on each input
card.
It is recommended to loop through no more than 8 frames or video performance may be affected beyond 8
frames.
If using more than 8 frames, the source signals must be split using multiple transmitters, cascading transmitters
via the local monitor output frames, using T4 multi output transmitters, or the MultiView 9D Cat5 distribution
amplifier.
7
8 Frames
8 Frames
Using two single port transmitters to split the video via the local monitor port of the first transmitter:
Using a T4 transmitter to feed input video to 8 frames at a time:
8 Frames
8 Frames
UTP
UTP
Video
In
Video out of local monitor port to input of second transmitter
UTP
Video
In
UTP