CHAPTER 1:  Specifications  

1 Specifications 

Video & Aux Signals: 

 

Signal configuration………………………4 , individually routable channels per RJ-45 jack. 
Input impedance.....................................100

 

balanced (Compatible with all MultiView equipment) 

Nominal input amplitude.........................1 Volt P-P 
Dynamic headroom ................................>3dB 
Gain from transmitter input to receiver  
 output through switch ...…………………Unity 
Coupling from transmitter input to 
 receiver output....…………………………DC 
Circuitry bandwidth .................................>220MHz 
Signal type ..............................................1,2,3,4 & 5 component video + aux channels (Via MultiView components) 
Input connectors (UTP)............................RJ-45 Female 
Input connectors (VGA)...........................HD15 female, 1/8” audio socket 
Loop out connectors.........................…....RJ-45 Female 
Output connectors…………………………RJ-45 female 

 

Audio: 

Audio signals are ported into the Mondo III Matrix via MutiView components or via a 3.5mm stereo audio jack for Mondo Direct. 
The type of transmitters and receivers used therefore defines audio specifications.  Please refer to the spec sheets for those 
components. 

 

RS 232 Serial: 

Serial signals are ported into the Mondo III Matrix via MultiView components or via a 3.5mm audio jack for simplex transmit  in a 
Mondo Direct. Transmission is uni-directional broadcast in this mode.  
Mondo III SAP versions allow bi-directional serial sessions with individual receivers. There are 8 DB9 COM ports on each Mondo 
III SAP frame That can be used in conjunction with SAP enabled receivers for full bi-directional RS232 communication with the 
device attached to the receiver. Reference Section 6 for SAP usage. 

 

Control: 

Protocol to switch…………………………RS-232/RS-422*, Selectable; 9600 baud standard,  

 

 

 

 

 

 

 

            (rate selectable to 9600, 19,200, 38,400, 57,600, 115,200)  

 

 

 

 

            8 data bits, 1 stop bit, no parity, no flow control. 

Interface connector, input………….….….DB9 or 7 position Phoenix** 
Interface connector, input………….….….USB mini B type (Mondo III SAP ONLY. Requires driver file: MONDO3_USB.inf) 
Interface connector,  
 Interframe communication, input/output………...3 position Phoenix or 7 position Phoenix (used for Mondo Legacy mode only)*** 
 
All input to output switching commands are received and processed by the master frame.  Additional frames used within the matrix 
are connected in a daisy chain and receive processed commands from the master frame. 
In Mondo III serial control mode, the BUS terminator switch must be ON for the first and last frames. 
 

*   The 7 pin phoenix serial input supports both RS-232 and RS-422 modes 
     The DB9 serial ports support RS-232 only 
**   When using Mondo III frames in a legacy Mondo system only the 7 pin phoenix serial connections are used. 
*** The BUS connector and DB9 ports are disabled in this mode. 

 

Power: 

Power input .............................................100-240V / 50~60Hz 
 

 

 

 

 Fused input. Replace fuse with same rating: 250V, 2.5A, Slow Blow, 5x20mm 

Consumption……………………………….200 W Max 
Redundancy………………………………..2 independent fully redundant AC Mains inputs. 
 

Environmental: 

Temperature/humidity  
 Storage ………………………………...….-40° to +158°F (-40° to +70°C) / 10% to 90%, non-condensing 
 Operating...........................………………...0° to +104°F (0° to +40°C) / 10% to 90%, non-condensing 
 

Mechanical: 

Rack mount ................................……..…Standard, 4U 19” EIA 
Enclosure type ..........................…………Front Panel: Powder coat over aluminum 
 

 

 

                 Enclosure: Aluminum 

Enclosure dimensions ......………………..7.0" H x 19" W x 10.25" D (178 mm H x 483 mm W x 260 mm D) 
Weight ................................…….………..16.6 lbs (7.5 kg) fully populated (shipping weight: 24 lbs (10.9 kg)) 
Compliances .............................…………CE, NRTL Listed,  FCC Part 15 
MTBF ......................................……….….100,000 hours 
 

Содержание Mondo III Matrix

Страница 1: ...1 Mondo III Matrix Installation Setup Guide...

Страница 2: ...either express or implied with respect to this software or documentation including their quality performance merchantability or fitness for a particular purpose As a result this software or documentat...

Страница 3: ...ations and flicker on low voltage supply systems for equipment with rated current up to and including 16A EN60950 1 2006 Safety for Information Technology Equipment EN55024 1998 A1 2001 A2 2003 Immuni...

Страница 4: ...rview Design Guidelines 4 3 Installation 14 4 Configuration 18 5 Commands 21 6 Mondo III SAP Design Configuration Usage 32 7 Troubleshooting 35 Appendix A Cable Pinouts 36 Appendix B Fan Filter Cleani...

Страница 5: ...S 232 RS 422 Selectable 9600 baud standard rate selectable to 9600 19 200 38 400 57 600 115 200 8 data bits 1 stop bit no parity no flow control Interface connector input DB9 or 7 position Phoenix Int...

Страница 6: ...ndo III environment see Section 4 Operational Mode command and Appendix A for legacy Mondo serial bus cabling Contact Magenta Research for details The Mondo Direct option allows a direct video connect...

Страница 7: ...9m of variance Add service loops as necessary Another option is to use the MorphIT Dual EQ option between the transmitter and switch input to normalize all cables to 0 ft prior to the switch Contact...

Страница 8: ...within a system 6 Inputs 1 16 Inputs 17 32 Inputs 33 48 Inputs 49 64 Outputs 1 16 Outputs 17 32 Inputs 1 16 Inputs 17 32 Inputs 33 48 Inputs 49 64 Outputs 1 16 Outputs 17 32 Inputs 65 80 Inputs 81 96...

Страница 9: ...re than 8 frames the source signals must be split using multiple transmitters cascading transmitters via the local monitor output frames using T4 multi output transmitters or the MultiView 9D Cat5 dis...

Страница 10: ...ctions in Section 4 Please follow Table 1 on page 9 for address guidelines Frame addressing is done via the LCD on the rear of the frame See Section 4 for details It is necessary to power cycle the fr...

Страница 11: ...Addr 74 Addr 106 Addr 138 161 176 ROW 12 Addr 11 Addr 43 Addr 75 Addr 107 Addr 139 177 192 ROW 13 Addr 12 Addr 44 Addr 76 Addr 108 Addr 140 193 208 ROW 14 Addr 13 Addr 45 Addr 77 Addr 109 Addr 141 209...

Страница 12: ...rce of video may be displayed while a single audio or serial signal is broadcast to one or more displays without changing the video signal Reference the Batch Routing Command set in Section 5 See the...

Страница 13: ...do III SAP option also features an additional USB control input that can be used with any serial terminal application on a PC A software driver MONDO3_USB inf is required to be installed on the host P...

Страница 14: ...DB9 COM ports that can be used for additional control options or in SAP mode The 7 pin phoenix connector labeled 1 7 may also be used as a control input COM port A USB port can also be used with a PC...

Страница 15: ...d is not automatic 1 Solid Green filter does not require service 2 Solid Red Filter requires service ALARM Indicates an alarm condition if any of the system elements shown on the dashboard are not ope...

Страница 16: ...ocation only Product may be powered by redundant power sources Disconnect all power sources before servicing 2 Before any cables are connected determine the Input Output assignments for each switch fr...

Страница 17: ...acy Mondo systems please use the 7 pin IN OUT Phoenix connectors for interframe communication see Appendix A for cable pinouts 5 Connect the control cable RS 232 between the controller device PC or th...

Страница 18: ...ix inputs Insert RJ45 cables gently pushing too hard may damage connector pins If a Mondo Direct input card is used connect video sources directly into the HD15 connectors Ensure cables click securely...

Страница 19: ...oses it is recommended to use a simple terminal control program such as Hyperterminal See Section 4 and 5 for set up and commands NOTE It is recommended to maintain cable lengths as equal as possible...

Страница 20: ...This is the idle display screen The UP and DOWN buttons may be used to adjust the display contrast The OK button will save the current LCD display contrast setting so that it will be restored after a...

Страница 21: ...values The OK button will select the next parameter When the last parameter has been configured it will save the current setting Setting Saved will be shown Parameters 1 Mode Port mode selection a Mod...

Страница 22: ...re not valid for Com 9 a Mode 1 Command port accepts switch control commands b Mode 2 Command port with event notification Same as Mode 1 but every time a switch cross point assignment changes an even...

Страница 23: ...for the OK ready prompt from the switch before sending the next command string The Mondo III Matrix master frame outputs information on its hardware and firmware platform as well as how many frames ar...

Страница 24: ...utput zzz zzz Rvvv Gwww Bxxx Ayyy Where zzz Output number specified vvv Red channel Input assignment UTP pair 2 www Green channel Input assignment UTP pair 3 xxx Blue channel Input assignment UTP pair...

Страница 25: ...d Video from Input 14 are routed to Output 13 V86 CR Video from Input 6 is routed to Output 8 A1412 CR Audio from Input 12 is routed to Output 14 To turn an output off route from Input 00 Example B160...

Страница 26: ...2 through 15 Y123 CR Send Video Only from Input 3 to Outputs 1 and 2 Z010516 CR Send Audio Only from Input 16 to Outputs 1 5 Conference Mode Cross Connect Commands J Both Video and Audio K Video Only...

Страница 27: ...en Channel 2nd Pair B Blue Channel 3rd Pair A Auxilliary Channel 4th Pair EE Take Execute Batch Commands Parameters xxx Output yyy Input If yyy 0 then the output will be turned off Examples Rxxxyyy CR...

Страница 28: ...ts per frame 16 32 48 or 64 are the only valid choices mm Frame address of the master frame in this system RTD Report temperature data M3 Report temperature data all frames Command RTD CR One line for...

Страница 29: ...ly fast air filter dirty Air filter status codes 0 filter OK 1 not implemented 2 filter needs changing now 3 not implemented The response is always in groups of 5 fields with a comma as the delimiter...

Страница 30: ...rameters Reset Factory Default Clears all settings and configuration parameters This will also disable your auxiliary serial ports COM1 2 USE WITH CAUTION SSP System Status Panel M3 Read status panel...

Страница 31: ...nteract with the switch that user will receive an ER03 response until the system is unlocked That user will need to retry that command later ALM Alarm Control M3 Enable Disable Mute the audible alarm...

Страница 32: ...ing LF CR OK LF CR frame Frame address Status info string frame PS1 PS1 PS2 PS2 BP BP CR OK frame frame address PS1 Power supply1 5V rail voltage PS1 Power supply1 5V rail voltage PS2 Power supply1 5V...

Страница 33: ...n Serial port channel 1 COM1 2 COM2 etc 9 COM9 the 7 pin phoenix connector labeled 1 7 link in RS 232 port b Baud rate 0 9600 1 19200 2 38400 3 57600 4 115200 x Auxiliary parameter COM1 8 aux power o...

Страница 34: ...e is enabled The SAP feature utilizes the fourth pair of the cat5 cable to send the serial signals to a receiver The SAP enabled receiver receives these commands and passes them out through its serial...

Страница 35: ...onfiguration Guidelines In order to utilize the SAP features on the Mondo III SAP frames with the COM ports in the last column must be set to SAP enabled This done via the LCD on the rear of the frame...

Страница 36: ...a f c LF CR OK LF CR Read all SAP output COM connections Command SCC CR or SCC CR Response p a f c LF CR p a f c LF CR OK LF CR Clear a COM port connection Command SCCp CR Response OK LF CR Clear all...

Страница 37: ...determining serial connectivity issues The GEO command may also be used to query the system and determine the reported matrix size to see if all slaves have been recognized Each slave frame will have...

Страница 38: ...cable can also be used in a legacy non Mondo III system for third party con trol Table A 2 Serial Interframe BUS cable for Mondo III This cable is only used in a Mondo III system and is used for inte...

Страница 39: ...n LCD Do not enable Aux Power on more than one COM port at a time Pin Tip Serial Tx SPDIF Left Ring N C N C Right Sleeve Serial GND SPDIG GND Signal Table A 4 1 8 3 5 mm Audio Serial Connection Mondo...

Страница 40: ...N1B 7 Table A 5 Interframe control cable for legacy Mondo systems If using a Mondo III frame in an older system with legacy Mondo frames It is re quired to set the Mondo III frame to M2 Mode via the L...

Страница 41: ...ut towards the rear Reference figure B 1 below The filter should be checked periodically and cleaned with a vacuum It is not rec ommended to immerse the filter in water Remember to reset fan Filter Se...

Страница 42: ...ith the USB port 2 When prompted by Windows to automatically search for a driver click No 3 Click to manually install driver and follow prompts 4 When Have disk option appears click and point to the C...

Страница 43: ...43 41 NOTES...

Страница 44: ...44 MAGENTA MONDO MATRIX Magenta Research 128 Litchfield Road New Milford CT 06776 USA 860 210 0546 FAX 860 210 1758 www magenta research com PN 5310218 01 rev 03 Jun 2011...

Отзывы: