![Magenta Mondo III Matrix Скачать руководство пользователя страница 8](http://html1.mh-extra.com/html/magenta/mondo-iii-matrix/mondo-iii-matrix_installation-and-setup-manual_3418143008.webp)
8
MAGENTA MONDO MATRIX
CHAPTER 2: Introduction
2.2 Design Guidelines, cont.
Mondo III Matrix Sizing
Mondo III Matrix frames are available in 16 output sizes. Inputs may vary from 1 to 64 in 16 port increments.
To add outputs, frames are cascaded “vertically” in “rows”.
To add inputs beyond the 64 input single frame limit, frames are cascaded “horizontally” in “columns”.
In the case of Mondo Direct frames, a maximum of 32 inputs is allowed.
All frames must have the same number of input ports within a system.
6
In
pu
ts 1
-1
6
Inp
u
ts
17
-3
2
Inp
u
ts
33
-4
8
Inp
u
ts
49
-6
4
Outputs
1-16
Outputs
17-32
Input
s 1-
16
Input
s 17-
32
Input
s 33-
48
Input
s 49-
64
Outputs
1-16
Outputs
17-32
Input
s 65-
80
Input
s 81-
96
In
put
s 97-
112
Outputs
1-16
Outputs
17-32
A 64 input by 16
output single frame
matrix switch
Add 16 outputs by
cascading vertically
in rows. The above
switch is now a 64
input by 32 output
two frame matrix
switch. A maximum
of 512 outputs are
possible.
Add 16 to 48 inputs
by cascading
horizontally in
columns. The above
switch is now a 112
input by 32 output 4
frame matrix switch.
A maximum of 256
inputs are possible.
Input
s 1-
16
In
puts 17-3
2
In
puts 33-4
8
In
puts 49-6
4
Outputs
1-16
Содержание Mondo III Matrix
Страница 1: ...1 Mondo III Matrix Installation Setup Guide...
Страница 43: ...43 41 NOTES...