5. Commands, cont.
Reporting/Configuration Commands:
$RPS – Report Power Status (M3)
Status of all frames:
Command: $RPS
<CR>
Response:
status
info
string
<LF><CR>
status info string
<LF><CR>
OK>
<LF><CR>
Status of one frame:
Command: $RPSframe
<CR>
Response:
status
info
string
<LF><CR>
OK>
<LF><CR>
frame
=
Frame
address
Status info string:
frame,PS1+,PS1-,PS2+,PS2-,BP+,BP-<CR>
OK>
frame = frame address
PS1+ = Power-supply1, +5V rail voltage
PS1- = Power-supply1, -5V rail voltage
PS2+ = Power-supply1, +5V rail voltage
PS2- = Power-supply1, -5V rail voltage
BP+ = Backplane, +5V rail voltage
BP- = Backplane, -5V rail voltage
The voltage value will be in the format of “+5.00” or “-5.00”, where 5.00 is replaced by the actual reading. A
failed supply rail will be reported as “0.00”.