48
✓
Try turning off/disconnecting AC power from both the preampli-
fier and the Nº39. After several seconds, restore AC power to the
preamplifier,
then
turn on the Nº39’s
main power
switch.
Never
operate the
main power
switch without first making sure
that power is turned off to your receiver, integrated ampli-
fier, or preamplifier/power amplifier.
✓
You may have older versions of the system software in your asso-
ciated Mark Levinson components which do not fully support all
Linked functions. Contact your Mark Levinson dealer with the
model and serial numbers of your Mark Levinson components. If
needed, new EPROMs will be provided at no charge.
7.
THE REMOTE CONTROL DOESN’T OPERATE THE Nº39.
✓
The Remote Control is at the wrong angle relative to the Nº39,
and the Nº39 can’t receive the signal.
✓
The sensor window on the front panel of the Nº39 is dirty or
blocked.
✓
The Remote Control’s projection lens is dirty.
✓
Fluorescent lighting or sunlight is interfering with the operation
of the Remote Control.
✓
The Remote Control’s batteries are weak and need to be replaced.
✓
The Remote Control’s batteries are installed incorrectly.