48
49
CONNE
CTION PLAN
CONNE
CTION PLAN
No function
Port 2
for MACO openDoor
access control systems
Port 1
for MACO openDoor
access control systems
Power supply
with UPS function:
Connection INSTINCT UPS module
without UPS function:
Connection INSTINCT power supply
INSTINCT Bus
for sash-side assembly:
Connection INSTINCT cable transition
for frame-side assembly:
Connection system cable
OUTPUT: Door open (Test Kit: OUTPUT 2)
Function:
indicates that all locks are properly unlocked.
Optionally as NO or NC signal:
10: NO
11: COM
12: NC
Examples:
Alarm system, smart home systems
OUTPUT: Closure monitoring (Test Kit: OUTPUT 1)
Function:
indicates whether all locks are properly locked.
Optionally as NO or NC signal:
7: NO
8: COM
9: NC
Examples:
Alarm system, smart home systems
INPUT: DAY RELEASE (Test Kit: DAY)
Function 1:
Connection for external components to activate/deactivate the day release (by 2-second,
uninterrupted actuation)
Function 2:
Connection for external components for one-time opening with upright locking of the locks (by
short actuation pulse) - if the door is not opened within 5 seconds, the locks lock again.
Examples:
Day release button, or intercom
INPUT: Door opening from outside (Test Kit: OPEN EXT)
Function:
Connection for external components to unlock the INSTINCT system
Special features:
Does not respond to parental control mode
Examples:
Intercom, external access control systems, smart home systems, etc.
INPUT: Door opening from inside (Test Kit: OPEN INT)
Function:
Connection for external components to unlock the INSTINCT system
Special features:
Responds to parental control mode (opening the door requires 5-second, uninterrupted
actuation) - Parental control is only available with INSTINCT Bluetooth module.
Example:
Opening switch
Connection plan INSTINCT Gateway
G
ND
US
P
+2
4V
G
ND
R
S 4
8
5 B
R
S 4
8
5 A
A
ddr
es
s l
in
e
+2
4V