32
33
± 2,5
± 2,5
TX 10
COMMISSIONING
WITH TEST
KIT
COMMISSIONING
WITH TEST
KIT
Commissioning with Test Kit
Commissioning with Test Kit
8. Check the contact pressure - for this the door can be unlocked via the INSTINCT Test Kit, the MACO
openDoor access control or via the INSTINCT App.
9. Press the OPEN INT button on the INSTINCT Test Kit to unlock all locks at the same time.
!
NOTES ON ADJUSTING THE
CONTACT PRESSURE
1. Set the pin position according to
default as per the system folder.
2. Check the height adjustment.
› Press the hook manually.
› Close the door carefully and check for
proper run-in.
› There is a marking on the locking hook
that simplifies adjustment depending
on the installation situation.
3. Check contact pressure and, if
necessary, adjust.
Kontrolle:
Output 2 lights up.
!
ERROR INDICATION
› when Output 1 and Output 2 are not lit.
› when Output 1 and Output 2 are lit.
Tone
Time
medium
medium
!
CONTROL SIGNAL - OPEN
If an acoustic module
has been installed,
the following
signal is heard: