214325
215
Revision A
Figure 5.159: John Deere Combine Display
7.
Select HEADER in box (A) by scrolling down to box
using scroll knob, and then pressing check mark button
(knob and button are shown in Figure
8.
Scroll down to lower right icon that resembles an arrow
in a diamond (B) and press check mark button to
select it.
Figure 5.160: John Deere Combine Control
Console
A - Scroll Knob
B - Check Mark Button
9.
Follow steps listed on combine display to perform the calibration.
NOTE:
If an error code appears on page, sensor is not in correct working range. Refer to
from Combine Cab (John Deere 70 Series), page 210
to check and adjust range.
Setting Sensitivity of Auto Header Height Control (John Deere 70 Series)
NOTE:
Changes may have been made to combine controls or display since this document was published. Refer to
combine operator
’
s manual for updates.