214325
242
Revision A
Figure 5.220: Float Indicator with Auto Header
Height Sensor
2.
The pointer (A) on float indicator should point at
0
. If it
does not, adjust cable bracket (B) until pointer (A) on
float indicator points to
0
.
Figure 5.221: Float Indicator Reading 1 V
3.
Measure voltage between ground and signal wires at
AHHC sensor in float indicator with a voltmeter (A).
NOTE:
The voltage reading should be below
4.3 V
.
Figure 5.222: Float Indicator Reading 4.3 V
4.
Fully lower combine feeder house until adapter is no
longer supporting header. The float indicator should
read
4
.
NOTE:
You may need to hold HEADER DOWN switch for a few
seconds to ensure feeder house is fully lowered.
5.
Measure voltage between ground and signal wires at
AHHC sensor in float indicator with a voltmeter (A). It
should be at low voltage limit for combine
–
0.7 V
.
6.
If sensor voltage is not within low and high limits, or if
range between low and high limits is less than
3.0 V
,
make adjustments according to