214325
207
Revision A
Figure 5.143: John Deere Combine Display
7.
Press UP or DOWN buttons until HDR appears on
monitor.
8.
Press ENTER button. HDR H-DN appears on monitor.
9.
Fully lower feeder house to ground.
NOTE:
You may need to hold HEADER DOWN switch for a few
seconds to ensure feeder house is fully lowered.
Figure 5.144: John Deere Combine Display
10. Press CAL button (A) to save calibration of header.
HDR H-UP appears on monitor.
11. Raise header three feet off ground and press CAL (A)
button. EOC appears on monitor.
12. Press ENTER button (B) to save calibration of header.
Your AHHC is now calibrated.
NOTE:
If an error code appears during calibration, sensor is out
of voltage range and will require adjustment. Refer to
Calibrating Auto Header Height Control (John Deere 60
Series), page 206
.
NOTE:
After calibration is complete, adjust combine operation
settings to ensure proper field operation.
Turning Accumulator Off (John Deere 60 Series)
NOTE:
Changes may have been made to combine controls or display since this document was published. Refer to
combine operator
’
s manual for updates.