214325
200
Revision A
Figure 5.128: John Deere Combine Display
1.
Press DIAGNOSTIC button (A) on monitor.
dIA
appears
on the monitor.
2.
Press UP button (B) until
EO1
appears on monitor, and
press ENTER (D). This is header adjustment.
3.
Press UP (B) or DOWN (C) button until
112
is displayed
on monitor. This is your sensitivity setting.
NOTE:
The lower the reading, the higher the sensitivity. Ideal
operating range is typically between 50 and 80.
4.
Press ENTER (D) to select
112
as sensitivity setting
(this will allow you to change first digit of number
sequence).
5.
Press UP (B) or DOWN (C) until desired number is
displayed, then press CAL (E) button. This will bring
you to second digit. Repeat this procedure until desired
setting is achieved.
6.
Press ENTER (D) to save changes.
NOTE:
The numbers depicted on displays in these illustrations
are for reference purposes only; they are not intended
to represent specific settings for your equipment.
Adjusting Threshold for Drop Rate Valve
This procedure explains how to adjust point at which restrictor valve opens allowing full flow to lift cylinders.
NOTE:
Changes may have been made to combine controls or display since this document was published. Refer to
combine operator
’
s manual for updates.
Figure 5.129: John Deere Combine Display
1.
Press DIAGNOSTIC button (A) on monitor.
dIA
appears
on the monitor.
2.
Press UP button (B) until
EO1
appears on monitor and
press ENTER (C). This is header adjustment.
3.
Press UP (B) or DOWN button until
114
is displayed on
top portion of monitor. This is setting that adjusts when
fast drop rate starts with respect to dead band.
NOTE:
The default setting is 100. Ideal operating range is
typically between 60 and 85.
4.
Press ENTER (C) to select
114
as fast drop rate (this
will allow you to change first digit of number sequence).
5.
Press UP (B) or DOWN (E) until desired number is
displayed, then press CAL button (D). This will bring
you to second digit. Repeat this procedure until desired
setting is achieved.
6.
Press ENTER (C) to save changes.
Содержание FFT FD75
Страница 2: ...FD75 FlexDraper Combine Header Published June 2017...
Страница 10: ......
Страница 24: ......
Страница 148: ......
Страница 188: ...214325 178 Revision A Figure 5 82 Combine Heads Up Display SETTING UP AUTO HEADER HEIGHT CONTROL...
Страница 282: ......
Страница 288: ......
Страница 304: ......
Страница 307: ......