Revision A
Checking Voltage Range from Combine Cab
Before checking voltage range, follow these steps:
1.
Position header 150 mm (6 in.) above ground, and unlock adapter float.
Figure 5.120: Float Lock
2.
Check that float lock linkage is on down stops
(washer [A] and nut [B] cannot be moved) at both
locations.
NOTE:
If header is not on down stops during next two steps,
voltage may go out of range during operation causing a
malfunction of AHHC system.
Figure 5.121: Float Indicator Box with Auto
Header Height Sensor
3.
The pointer (A) on float indicator box should point at
0
.
If it does not point at zero, adjust cable take-up
bracket (B) until it does.