214325
188
Revision A
Figure 5.102: Calibration
2.
Touch CALIBRATE (A) at bottom right of page. The
HEADER CALIBRATION page displays.
Figure 5.103: Header Calibration Page
The right of page shows calibration information (A).
Results are shown for a variety of sensors (B) at top
of list:
•
Left and right header sensor (V) (values will be same
with MacDon headers)
•
Header height sensor (mA)
•
Tilt position sensor (mA)
The modes applicable to MacDon headers are shown
with check marks below line (C):
•
Return to cut
•
Automatic header height control
CAUTION
Clear the area of other persons, pets, etc. Keep children away from machinery. Walk around the machine
to be sure no one is under, on, or close to it.
Figure 5.104: Header Down Switch
3.
On ground speed lever (GSL), press HEADER DOWN
button (A). Sensor values start changing on HEADER
CALIBRATION page as header lowers.
NOTE:
The header needs to be lowered all the way, and then
raised off ground. The range should be between
0.5
and 4.5 V
. If value is not in that range, sensor needs to
be adjusted.