LION Bus Coupler
▪
Configuration
52
MD_Com-Parameter:
PD-Com-Parameter:
Telegrams
To add a TRDP Telegram select "Telegrams" from the project tree in the left.
A list of all existing telegrams is shown.
Confirm-Timeout
[us]
Default comfirm timeout time
(see IEC 61375-2-3 for details)
Reply-Timeout
[us]
Default reply timeout
(see IEC 61375-2-3 for details)
Connect-Timeout
[us]
Default connect timeout (see IEC 61375-2-3 for details)
TTL
Default time to live of a message data packet
QOS
Default quality of service of message data
Protocol
Default protocoll used for message data:
- UDP
- TCP (not implemented on SIL0 bus coupler)
UDP-Port
The UDP Port, typically 17225
TCP-Port
The TCP Port, typically 17225
Num-Sessions
Maximum number of simultaneous message data
sessions
Retries
Number of retries in a message data session
TimeoutValue
[us]
Default timeout value in microsecconds
TTL
Default time to live for process data packets
QOS
Default Quality of Service for process data
Validity-
Behaviour
Default Validity behaviour:
- Zero
- Keep
Port
UDP Port used for process data communication,
typically 17224