LION Bus Coupler
▪
Configuration
50
Add Elements to Datasets
Elements need to be added to datasets to transfer data. A dataset can be used
to store elements or as a Diagnostic Dataset.
Diagnostic Data Set:
Element Descriptions:
Nesting of Datasets:
The bus coupler supports nesting of datasets up to a depth of 5.
As soon as a dataset exists it is possible to use it as an element in another
dataset. By doing this it is possible to reduce redundant information if the same
data structure is needed multiple times.
Be careful not to add circular dependencies. These lead to errors in the
configuration.
Use as diagnostic
DataSet
Click to add diagnostic data to the DataSet. Afterwards the
structure of the diagnostic dataset is loaded. A manual
editing of the structure of the diagnostic dataset is not
possible.
Name
Name of the element (for documentation purpose only)
ArraySize
Number of elements of the same type in an array (0 for
dynamic size is not supported by the bus coupler)
Scale
Not used by the bus coupler.
(see IEC 61375-2-3 for description)
Type
Data type of the element e.g. BITSET8 for digital I/O
Unit
Not used by the bus coupler.
(see IEC 61375-2-3 for description)
Offset
Not used by the bus coupler.
(see IEC 61375-2-3 for description)
Содержание 803012
Страница 1: ...Operating Instructions LION Bus Coupler Ethernet SIL0 LION BC ETH LUE 803012 Version 01 03 19 2019 ...
Страница 63: ...LION Bus Coupler Operation 64 Module not recognized Unexpected module ...
Страница 64: ...LION Bus Coupler Operation 65 Wrong safety checksum ...
Страница 75: ... by Lütze Transportation GmbH Weinstadt Germany Technical changes reserved ...