LION Bus Coupler
▪
Configuration
42
9
Configuration
The bus coupler communicates with the I/O modules via L-Bus
2
with a safe
protocol. The bus coupler sends data to the I/Os or data will be received from the
I/Os. For the communication, a mapping of data between bus coupler and I/Os
has to be done. Therefore, the process-data image of the IOs has to be mapped
on the datasets of the bus coupler's source or sink telegrams.
The mapping and configuration of the data has to be done in the LION
Framework.
9.1
TDB
The TRDP bus coupler only supports the Trdp Data Base (tdb) file format.
The configuration is saved in an TDB file, which is relevant for the TRDP
communication. The file is generated by the LION Configuration Framework and
can be loaded on the bus coupler via the webserver.
9.2
Configuration Data Values
The project planner is responsible for the configuration. Especially for
the correct mapping of the process and diagnosis data between bus
coupler and I/O modules.
Maximum TDB length
3F00h
Maximum number Telegrams
32
Maximum number of Datasets
64
Maximum number of Elements per
Dataset
128
Maximum Number of Com para-
meters
32
Maximum Number of mappings
per direction
512
Maximum size of a Process Data
Telegram (payload)
1432 Byte
Maximum size of a Message Data
Telegram (payload) (UDP frag-
mentation is not supported)
1352 Byte
Содержание 803012
Страница 1: ...Operating Instructions LION Bus Coupler Ethernet SIL0 LION BC ETH LUE 803012 Version 01 03 19 2019 ...
Страница 63: ...LION Bus Coupler Operation 64 Module not recognized Unexpected module ...
Страница 64: ...LION Bus Coupler Operation 65 Wrong safety checksum ...
Страница 75: ... by Lütze Transportation GmbH Weinstadt Germany Technical changes reserved ...