5.5 Operating a three-phase motor with attached frequency converter
Default setting:
"Start"
button starts the pump
"Stop"
button stops the pump
button (reverse rotating direction) without function
Button
I
activates mode I: "Pumping"
Button
II
activates mode II: "Emptying"
"Reset"
button resets the pump in the case of malfunction
Speed controller
(Potentiometer) for manual speed
adjustment
Pumping
Rotating to the right
Target value set at
potentiometer
(10-50 Hz)
Emptying
Rotating to the left
Fixed speed 5 Hz
(optionally without
function)
5.6 Mechanical loads on the pump tube
The pump tube’s functioning and service life are impaired when deformed by mechanical loads. For this reason,
the outlet must not be subjected to compressive or tensile forces.
► The bending moment M
B
at the outlet must not exceed 50 Nm (→ Fig. 7).
5.7 Maximum immersion depth
► Make sure that the pump is not submerged further than its discharge port (→ Fig. 1).
5.8 Assembly in the container
► Fasten the pump in the container. Make sure that the container with the installed pump is enough stable even
in empty condition. This is of special attention with small containers.
► Push the splash guard on the pump tube downwards until the container opening is covered completely.
Содержание B70V-H-D SanitaryPlus
Страница 2: ...2 0698 5l51 B70V H SanitaryPlus 01 18 en...
Страница 3: ...3 0698 551 B70V H SanitaryPlus 01 18 Fig 1 Fig 2 Fig 3 Fig 4 Fig 5 Fig 6...
Страница 4: ...4 0698 5l51 B70V H SanitaryPlus 01 18 Fig 7 Fig 8 Fig 9 Fig 10 Fig 11 Fig 12...
Страница 5: ...5 0698 551 B70V H SanitaryPlus 01 18 Fig 13 Fig 14 Fig 15 Fig 16 Fig 17 Fig 18...
Страница 6: ...6 0698 5l51 B70V H SanitaryPlus 01 18 Fig 19 Fig 20 Fig 21...
Страница 7: ...7 0698 551 B70V H SanitaryPlus 01 18 Fig 24 Fig 25 Fig 26 Fig 28...
Страница 30: ...30 0698 5l51 B70V H SanitaryPlus 01 18 en...