21
0698-551 B70V
-H SanitaryPlus - 01/18
en
5.1 Installation of B70V-H-D SanitaryPlus
3
Motor is switched off
The three-phase drives are connected with the pump by means of a quick fastener.
Two stop pins (→ Fig. 2, Item 1) and two locking screws (→ Fig. 2, Item 2) are pre-assembled in the fastening
screw threads of the motors.
► Before assembly the jaw-type coupling must be adjusted at the motor and pump side (→ Fig. 2 - Item 3).
► Attach the motor onto the pump tube. The both locking screws here must be in accordance with the large
bores at the flange of the pump tube (→ Fig. 2 - Item 4).
► After a turning of the motor at block position (→ Fig. 3 - Item 1) the both locking screws can be tightened
(→ Fig. 3 - Item 2).
5.2 Installation of B70V-H-SR SanitaryPlus
3
Motor is switched off
► Attach the pump motor onto the pump tube (→ Fig. 4). The motor must be turned slightly to ensure that the
driver engages correctly in the coupling of the pump tube. Connect the motor and the pump tube with the
hand wheel (right-hand thread).
► Ensure that the pump is fitted correctly and securely.
5.3 Notices regarding start-up
!
WARNING
Risk of injury by crushing!
► When mounting the motor on the pump tube, hold the motor in such a way that no limbs can be squeezed
between the motor and the pump tube.
► When inserting the pump tube into a container, position your hands in a way that no pinching between the
pump tube and the container can happen.
► When using lifting equipment, ensure the proper use of the lifting equipment. Observe the operating instructions
of the lifting equipment.
5.4 Electrical connection of three-phase motors
!
DANGER
The electrical connection may only be carried out by trained qualified personnel. Following regulations
must be observed:
3
All works must only be carried out in voltage-free condition of the motor. Protection switch must be set to
OFF-position.
3
Mains voltage and frequency are as specified on the rating plate (→ Fig. 5).
3
Dimension of the connecting cable must be adjusted to the nominal current.
3
The insulation of the connecting cable must be adjusted to the environmental conditions.
3
The motor must rotate in the direction indicated by the arrow (→ Fig. 6). Reconnect the motor as necessary.
Содержание B70V-H-D SanitaryPlus
Страница 2: ...2 0698 5l51 B70V H SanitaryPlus 01 18 en...
Страница 3: ...3 0698 551 B70V H SanitaryPlus 01 18 Fig 1 Fig 2 Fig 3 Fig 4 Fig 5 Fig 6...
Страница 4: ...4 0698 5l51 B70V H SanitaryPlus 01 18 Fig 7 Fig 8 Fig 9 Fig 10 Fig 11 Fig 12...
Страница 5: ...5 0698 551 B70V H SanitaryPlus 01 18 Fig 13 Fig 14 Fig 15 Fig 16 Fig 17 Fig 18...
Страница 6: ...6 0698 5l51 B70V H SanitaryPlus 01 18 Fig 19 Fig 20 Fig 21...
Страница 7: ...7 0698 551 B70V H SanitaryPlus 01 18 Fig 24 Fig 25 Fig 26 Fig 28...
Страница 30: ...30 0698 5l51 B70V H SanitaryPlus 01 18 en...