15
0698-551 B70V
-H SanitaryPlus - 01/18
en
2.2.1 Technical data
Pump size
12.1
25.1
25.2
50.1
75.1
Operating pressure up to (bar)
6
8
10
8
8
Flow rate up to (l/min)
12
25
25
50
75
Viscosity max. (mPas)
100000 (30000*)
Medium temperature max. (°C)
100
100
100
100
100
Ambient temperature (°C)
-20 up to 40
-20 up to 40
-20 up to 40
-20 up to 40
-20 up to 40
Speed max. (rpm)
900
900
900
900
900
* Type B70V-H-SR
Part
Material
Immersion tube, rotor, drive shaft and retaining ring
SS 1.4404, 1.4571, 1.4462, 1.4401
O-rings
EPDM, FPM
Mechanical seal
Silicium carbide / Hard carbon alternatively: SiC / SiC
Stator
PTFE, EPDM
2.2.2 Operation in hazardous location or pumping flammable liquids
Application in explosion hazard areas or pumping flammable liquids the following points must be noted additionally:
► The operator must create an explosion protection document for his field of application. This document must
indicate the division of the explosive area into zones. Only devices of category 1 may be used in areas of
zone 0 and devices of category 1 or 2 in areas of zone 1.
i
The drum pumps are used to pump liquid products from mobile vessels. Inside of the container or the pump,
i.e. outer tube, inner tube with pump shaft, shaft sealing and pump tube, requirements of category 1 are
valid. For all other parts of the drum pump requirements of category 2 are valid.
Only use drum pumps with ATEX approval in explosion hazardous areas. Only use explosion proof drive motors
as well.
- B70V-H-D SanitaryPlus:
The drive motors (electrical or with compressed air drives) must be chosen according
to the respective size with a power of up to 2 kW and a maximum speed of 900 rpm.
- B70V-H-SR SanitaryPlus:
Universal motors with a power of up to 1.5 kW and a max. speed of 14400 1/min.
Содержание B70V-H-D SanitaryPlus
Страница 2: ...2 0698 5l51 B70V H SanitaryPlus 01 18 en...
Страница 3: ...3 0698 551 B70V H SanitaryPlus 01 18 Fig 1 Fig 2 Fig 3 Fig 4 Fig 5 Fig 6...
Страница 4: ...4 0698 5l51 B70V H SanitaryPlus 01 18 Fig 7 Fig 8 Fig 9 Fig 10 Fig 11 Fig 12...
Страница 5: ...5 0698 551 B70V H SanitaryPlus 01 18 Fig 13 Fig 14 Fig 15 Fig 16 Fig 17 Fig 18...
Страница 6: ...6 0698 5l51 B70V H SanitaryPlus 01 18 Fig 19 Fig 20 Fig 21...
Страница 7: ...7 0698 551 B70V H SanitaryPlus 01 18 Fig 24 Fig 25 Fig 26 Fig 28...
Страница 30: ...30 0698 5l51 B70V H SanitaryPlus 01 18 en...