User Manual CM-CAN1
3-5
3 Commissioning and configuration
DE
EN
3
3.5
Data handling
3.5.1 Saving settings
All configuration data can be backed-up with the K
EY
P
AD
on a S
MART
-
C
ARD
or with the D
RIVE
M
ANAGER
as a file. A parameter set in the
D
RIVE
M
ANAGER
always comprises three files with the extensions *.00D,
*.00T and *.00X. The D
RIVE
M
ANAGER
file selection boxes only ever
display the *.00D file.
3.5.2 Restoring
factory defaults
Note:
In both cases it takes around 10 seconds for the device to
signal that it is ready again. During this time the device per-
forms a self-test and changes all its settings to the factory
setting. This setup is only retained when the data are backed-
up in the device, however. Data backup is initiated by way of
the D
RIVE
M
ANAGER
user interface or by writing to parameter
150-SAVE = (1)START by way of the bus system.
Attention: Data backup takes a few hundred milliseconds.
During that time the device must not be switched off, other-
wise the settings will be lost.
Parameter 150-SAVE is automatically set to (0)STOP by the device after
the save operation. This process can be used for timeout monitoring of
the function.
Function
Effect
•
Parameter 04-PROG = 1
(subject area _86SY System)
➢
All parameters
of the current
user
data sets up to user level
MODE = 4
are reset to their factory defaults.
•
Press and hold down both cursor
keys during power-on.
➢
All parameters in
all
user data sets
up to user level
MODE = 5
are reset
to their factory defaults.
•
Parameter 4-PROG = 850
(...)
➢
All parameters in
all
user data sets
up to user level
MODE = 6
are reset
to their factory defaults.
Содержание CM-CAN1
Страница 8: ...User Manual CM CAN1...
Страница 28: ...3 6 User Manual CM CAN1 3 Commissioning and configuration...
Страница 50: ...4 22 User Manual CM CAN1 4 Setting the device parameters...
Страница 72: ...6 8 User Manual CM CAN1 6 Fault rectification...
Страница 78: ...7 6 User Manual CM CAN1 7 Examples...
Страница 83: ......