3-2
User Manual CM-CAN1
3 Commissioning and configuration
3.1
Commissioning
sequence
Figure 3.1 If the initialization is correct parameter 578-OPTN2 shows LCAN.
Step
Action
Comment
1
Wire the drive unit as specified in the
Operation Manual.
To test CAN communication, it is
sufficient to connect the mains
voltage and activate the ENPO
signal (hardware enable) at
terminal X2/8.
2
Mount the communication module at
option slot 2 (X7).
3
Check the wiring. Make sure hardware
enable ENPO is not connected.
4
Switch on the supply voltage.
The green LED H5 on the
communication module
CM-CAN1 is lit steadily.
5
If the initialization was completed cor-
rectly, parameter 578 -OPTN2 in subject
area _57OP, Option modules, displays the
value LCAN. Please check the parameter
(See Figure 3.1).
If it does not show the value,
refer to section 3.3.