A-2
CDD3000-HF Operation Manual
A.1
Technical data
CDD32.003-HF to CDD34.006-HF
1)
Data referred to output voltage 230 V/400 V
and switching frequency 8 kHz
Designation
Technical data
CDD
32.
003-
H
F
CDD
32.
004-
H
F
CDD
32.
006-
H
F
CDD
32.
008-
H
F
CDD
34.
003-
H
F
CDD
34.
005-
H
F
CDD
34.
006-
H
F
Output, motor end
1)
Device rated power
1.0 kVA
1.6 kVA
2.2 kVA
2.8 kVA
1.5 kVA
2.8 kVA
3.9 kVA
voltage
3 x 0 ... 230 V
3 x 0 ... 400/460 V
Continuous current (RMS) (I
N
)
2.4 A
4.0 A
5.5 A
7.1 A
2.2 A
4.1 A
5.7 A
Peak current 1.8 x I
N
for 30 s
4.3 A
7.2 A
9.9 A
12.8 A
4.0 A
7.4 A
10.3 A
Rotating field frequency
0 ... 1600 Hz
Switching frequency of power stage
4,
8
, 12, 16 kHz
Input, mains side
Mains voltage
1 x 230 V
-20 % +15 %
3 x 400 V / 3 x 460 V
-25 % +10 %
Current (with line choke)
4.4 A
7.3 A
10.0 A
12.9 A
2.3 A
4.3 A
6.0 A
Asymmetry of mains voltage
–
±3 % max.
Frequency
50/60 Hz ±10 %
50/60 Hz ±10 %
Power loss at 4 / 8.16 kHz [W]
49 / 52
63 / 70
90 / 97
110 / 120
70 / 85
95 / 127
121 / 163
Braking chopper power electronics
Peak braking power with int.
braking resistor (only with version
CDD34 ..., Wx.x, BR)
-
-
–
–
1.6 kW
at 360
Ω
Minimum ohmic resistance of an
externally installed braking resistor
100
Ω
56
Ω
180
Ω