4-12
CDD3000-HF Operation Manual
4 Commissioning
Click on the “Other Motor” button on the “Motor” tab to select the right
motor from your installed database. The motor type is indicated on its
name plate. If the motor data set is supplied on a data carrier (floppy disk,
CD-ROM), it can be loaded directly by clicking on the “Change directory”
button.
If you are using a motor which is not in the database, Lust Antriebstechnik
GmbH offers custom data sets as a special service. Please consult your
project engineer on this.
Setting of the rotary encoder
The rotary encoder connected to the motor is set up on the Encoder tab.
Resolvers are assigned the abbreviation Rx, encoders Gx. The encoder
used is entered on the motor name plate.
Example:
Type ASM-11-20R23 specifies the setting by the designation R2
(resolver, 2 pole pairs), here shown in bold as an example.
When selecting a user-defined encoder type, the settings are entered
under “Optionen...”. For notes on the specification of rotary encoders refer
to Appendix A.5.
The automatic track signal correction enhances the smooth running of the
drive. It can be applied with values stored once on the basis of a teach-in
process, or in online adaptive mode.