3-20
CDD3000-HF Operation Manual
3 Installation
3.6.2 Standard
terminal
assignment
Terminal assignment in factory setting.
Figure 3.9 Standard terminal assignment
Features
•
Preset solution, speed control with
+ 10 V reference input (ISA00)
X2
Des.
Function
20
OSD03
Not assigned
19
GND03
Not assigned
18
VCC03
Not assigned
17
OSD02
Not assigned
16
OSD02
Not assigned
15
OSD01
Loop control active
14
OSD00
Device ready
13
DGND
Digital ground
12
ISD04
Not assigned
11
ISD03
Not assigned
10
ISD02
Not assigned
9
ISD01
Not assigned
8
ISD00
Start loop control
7
ENPO
Hardware enable of power
6
DGND
Digital ground
5
U
V
Auxiliary voltage 24 V
4
ISA01-
Not assigned
3
ISA01+
Not assigned
2
ISA00-
Differential analog reference -
1
ISA00+
Differential analog ref
Note the following points:
•
For terminal assignments for further preset solutions refer to
CDD3000 Application Manual.
ENPO
START
ACTIV
C_RDY
ISA0-
ISA0+
+10 V
ISA0-
ISA0+
or
CNC or