5
luminancebrands.com
Please contact 1-800-777-4440 for further assistance
Model No.: RCK55
Reverse Module Installation (Continued)
2.8: All Ceiling Fan Models.
20. Position the New Reverse Module (supplied)
into the Switch Housing.
21. Connect the Reverse Module Connector to the
Motor Connector (Figure 8).
22. The Connectors are Color-Coded and Keyed and
can be connected in only one manner.
REVERSE
MODULE
COLOR-CODED
MOTOR CONNECTOR
COLOR-CODED
REVERSE MODULE
CONNECTOR
Figure 8
REVERSE
MODULE
REVERSE MODULE
WHITE WIRE
MOTOR WHITE
WIRE
MOTOR & REVERSE MODULE
BLUE WIRES
WIRE
CONNECTOR
Figure 9
2.9: All Ceiling Fan Models.
23. Using a Wire Connector (supplied), connect the
Motor White Wire to the Reverse Module White
Wire (Figure 9).
24. Using a Wire Connector (supplied), connect the
Motor Blue Wire to the Reverse Module Blue Wire
(Figure 9).
NOTE: If you are planning to install an optional
Luminance Brands Light Fixture on your ceiling fan,
do not install the housing cover (Step 10) at this time.
HOUSING COVER
(TYPICAL)
SCREWS (2)
SWITCH
HOUSING
Figure 10
2.10: All Ceiling Fan Models.
25. Position the Switch Housing Cover (Figure 10)
on the Switch Housing and secure using the
Two Screws previously removed in Section 2.1,
Step 1.
26. Place the Fan Housing (top of motor facing
upward) in the lower styrofoam pad. The lower
pad serves as a holder for the Fan during the
following procedures.