![Lumen Dynamics Group OmniCure LX400+ Скачать руководство пользователя страница 53](http://html1.mh-extra.com/html/lumen-dynamics-group/omnicure-lx400/omnicure-lx400_user-manual_1947995053.webp)
- 48 -
LX400+ UV LED Spot Curing System
9.
Troubleshooting
9.1.1
When a system error occurs the 4 digit, 7 segment
display will flash. When head error occurs the LED
indicator will flash.
9.1.2
The display will show system level error codes without
the channel selection button having to be pressed.
9.1.3
The head level error codes will be displayed by
pressing and holding the channel select button that is
flashing. Once an error message has been shown it is
cleared. All head error messages will be queued and
displayed by subsequent pressing and holding of the
channel select button that is flashing.
9.1.4
When an error occurs, the current active exposure will
be terminated immediately.
9.1.5
On any head level error condition, the alarm PLC
output will be activated. The alarm PLC output will be
cleared when all messages in the error queue have
been cleared.
9.2
Error Codes (System Specific)
Err1;
Internal hardware error.
Err2;
Internal Communication failure.
Err3;
Non-Volatile Memory error.
Err4;
Button being pressed during power on.