- 25 -
LX400+ UV LED Spot Curing System
5.4
Output Emission Level Control
5.4.1
Controls the emission output setting of each individual
LED head.
5.4.2
Press and release the
MODE
button to access the out-
put
LEVEL
control. The
LEVEL
LED will light up (color
green).
5.4.3
Press the channel select button of the installed
head(s). The display will show the last saved emission
value of each selected head channel.
5.4.4
Press and release the
UP/DOWN
button to increase or
decrease the emissions output value in 1%
increments. Range is 15%-100%.
5.4.5
Press and hold the
UP/DOWN
button to rapidly
increase or decrease the emissions output value.
Range is 15%-100%.
5.4.6
When selection is below 15%, the channel is disabled
and the display shows
OFF.
5.5
„OFF‟ Indication Awareness
5.5.1
Displays
„OFF‟
when FP-2, FP-3, or FP-4 are selected
), and the channel being displayed
finishes its exposure before the other channels within
the group. The
„OFF‟
will be displayed until all
channels within the group finish their exposure.