Technical Data
Revision R09, November 2016
13
Operating safety
Environmental compliance
ISO 10109-11
Protection class
1
Internal protection standard IP 65
EMC
EN 61326 class B
Light source
Laser protection class 1M under DIN EN 60825-1
Certification
CE
Operating conditions
Temperature range
-40 °C to +55 °C
Rel. air humidity
0 % to 100 %
Wind
55 m/s
Physical dimensions
Dimensions of casing
W x H x L = 0.5 m x 0.5 m x 1.55 m
Packed dimensions
W x H x L = 0.65 m x 0.8 m x 1.67 m
Weight
70 kg (complete system)
9.5 kg (laser optical unit - heaviest spare part)
Installation requirements
Suitable low-voltage distribu-
tion systems
TN-S-system: grounded supply network, CHM 15k casing grounded,
neutral and protective conductor as separate wires
TN-C-system: CHM 15k casing grounded, neutral and protective
conductor in one single wire
Type of connection
Non-detachable connection
Requirements to be met by Owner/Operator
Lightning protection
External lightning protection to DIN V VDE 0185-3
Grounding
Grounding system to DIN V VDE 0185-3
Requirements for outdoor
installation
- Circuit breaker to cut low-voltage power supply, installed near the
CHM 15k
- Within easy reach
- Clearly marked as a part of CHM 15k
- Back-up fuse matched to wire cross-section
6 A, B or C
Table 2: Technical data