The 8400-Series Voice Terminals Instructions for Installation, Switch,
Administration, and Programming the Options
555-015-725
Issue 1
October 1996
Switch Administration
Page 5-9
Administering the 8405, 8410, and 8411 Voice Terminals
5
NOTE:
Notes on 8411Administration (if used with DEFINITY G3V4, Issue 3, or
later): The 8411B can be administered as itself ONLY IF it is connected to a
DEFINITY G3V4, Issue 3, (or later) switch. In Native Mode the voice
terminal is administered through a digital line circuit card with a line number
(with the usual three call appearances) assigned to the I-1 Channel. A
second line number can be administered through the same digital line card
on the I-2 Channel, but this line number can only be used for Analog
Adjuncts connected to the Analog Adjunct jack on the 8411. This Analog
Adjunct is assigned a private number, but can be used only for placing or
terminating a call. It cannot be used for any other analog functions such as
transferring a call or setting up a conference call. If a second line on the
8411 is administered on the I-2 Channel (for analog equipment) on the 8411,
type “analog” in the Data Option field on the administration screen.
If the 8411 is connected to a personal computer for use with PassageWay
software, type a “y” in the PassageWay field also on the administration
screen. (However, DO NOT enter a “y” in the PassageWay field unless the
user has a licensed PassageWay application.)
Table 5-5.
Administering the 8411B Voice Terminal
If you have this System
and this
Release
(which can
support this
type of
operation)
Administer
the 8411B as a
System 75
R1V1 —
R1V3
4-wire only
7403D
System 85
R2V2 —
R2V4
4-wire only
7403D
International System 75
IR1V4, etc.
4-wire only
7403D
DEFINITY G1
4-wire only
7403D
Global DEFINITY ‘91
4-wire only
7410D
DEFINITY G2V1
4-wire only
7410D
DEFINITY G2V2
4-wire only
7410 Plus
DEFINITY G3i, G3r, G3s,
G3vs
4-wire only
7410D
DEFINITY G3V2
2- or 4-wire
7410 Plus
DEFINITY G3V3 and G3V4,
Issue 1 and 2
2- or 4-wire
8410B
DEFINITY G3V3 or later
(including the DEFINITY ECS)
2- or 4-wire
8411B