UNITOUR Power System
User Manual
Page 52
Optional ability to send SMS messages to relevant personnel
if a problem arises (Future feature)
Neutral loss and over-voltage protection. The rack will shut
down in the event of a dropped neutral until the fault is
rectified, thus helping to protect attached equipment
Configurable warning alarms for over-current, temperature,
tripped breakers, phase loss and control signal loss
Mechanical
Fully clad flight case with removable front and rear lids fitted
with high-quality hardware. Removable top lid fitted when
patch option included
Optional swing-and-fold door roadcase available on request
Four slots for either USMT or UDMT Quick-Swap 12 channel
modules each protected by 63A 4-pole MCB (MFBL type)
Choice of dual (paired) Socapex 19-pin or Wieland 16-pole
multipin outlets. Total 16 6-circuit connectors
400A 4-pole MCCB main circuit breaker (auto-switch) on input
Optional programmable RCD module for 400A circuit breaker,
controlled from UHM control module
PowerLock 400A, 5-wire (TN-S) 230/415V supply in and thru
CEE 32A 3-phase auxiliary power output socket; Australian
models fitted with 32A 3-phase output socket protected by
32A 4-pole RCBO (Type A)
Three CEE 16A single-phase auxiliary power output sockets;
Australian models fitted with HPM 20A 3-pin output sockets
each protected by 16A single-pole RCBO (Type A)
M12 earth bond stud
Five colour indicators located on front and rear of mains distro
showing correct or bad connection of power supply
Optional 2:1 patch module with Wieland ST18 in/out
connectors (patch leads not supplied) plus two ST18
connectors and ammeter for load/lamp testing connectors
USMT smart power
module
QuickSwap - user swappable 12Ch x 16A relay module
Zero-cross switching of loads ensures that switched power
circuits are turned on at the zero-cross point on the sinewave
to minimise nuisance tripping of circuit breakers
Auto-power staggered start-up to sequentially switch on user-
selected channels from the touch screen or when a control
signal is detected
TCP/IP, UDP or DMX relay mode configurable per channel