UNITOUR Power System
User Manual
Page 35
last channel
in the range. Tap
ALL
to select all channels. Tap
CLEAR
to de-select all
channels. Tap
LAST
to recall your previously cleared selection.
Channels can also be selected by pressing their
CHANNEL SELECT
button located above
each
channel’s circuit breaker. To select a range of channels using the CHANNEL SELECT
buttons, press and
HOLD the first button
in the range then press the
last button
in the range.
When the required channel number(s) are selected (magenta) tap
DONE
.
When a channel(s) has been selected, the buttons on the “Dimmer Setup” menu become
active.
The “Dimmer Setup” menu provides the following functions:
•
MIN LEVEL
•
MAX LEVEL
•
CURVES
These functions are described in the following sections.
3.13.2
Min Level
Dimmer channels can have a minimum level.
“Min Level” sets a low level threshold. If the
control signal is below this level, the dimmer will be off.
To set a minimum level for a channel(s), from the “DIMMER SETUP Menu” tap
MIN LEVEL
.
The previously selected channel(s) are still valid. If you want to change your selection tap
SELECT CHANNELS
or use the
CHANNEL SELECT
buttons located on the output modules
to select the channel(s).
Set the minimum level by either entering the number on the touchscreen keypad or tapping
the
or
arrows.
Min Level
3.13.3
Max Level
Dimmer channels can have a maximum level.
“Max Level” sets the level of the dimmer output
when its control signal is at maximum. For example, setting this value to 90% will extend the
life of an incandescent lamp as it never operates on full voltage or setting it to 50% provides
115 volt output.
Note: The actual output voltage of the dimmer channel is dependent upon the dimmer curve.
LSC recommends that you measure the output voltage (with a 240 volt load connected) to
determine the “Max” level setting you require for a specific maximum voltage. This procedure
should only be carried out by suitably qualified personnel.