There are two choices of fan control,
•
Auto Speed
. The fan runs automatically when required. The higher the temperature the
faster the fan runs
•
Constant Speed
. The fan runs constantly at a speed that you set from the touch screen. The
speed range is from 0 to 100%. The letter “C” is displayed beside the fan symbol on the home
page. If the temperature exceeds 65 Celsius the fan will run at full speed
5.12.4
Import Export
The configuration and/or dimmer curve of your GEN·VI dimmer can be exported to or imported from
an SD card. This is useful for cloning the configuration to other units or for archiving. The SD card
slot is located on the front panel. The c
onfiguration file name is fixed as “GNW_CFG.XML”. If you
need to use multiple configurations than you should either use a separate SD card for each
configuration or use a single SD card and manage your files on a computer.
To export or import a file press
Config
,
System
,
Import/Export
.
If there is no SD card in the dimmer or no file on the card then the import buttons are greyed out.
5.13
Lock / Unlock
To
lock
the touch screen of the GEN·VI and prevent unauthorised access press
Config
.
Pressing the “Padlock” symbol provides 2 levels of lock.
•
User. Locks out the “Config”, “Riggers Control” and “DMX Address” menus
•
Service. Locks out the “Service” menu
Note
: The “Service” menu is used for factory setup and has no user functions. It is always locked.
Lock/Unlock