Gen VI Dimmer
User Manual
Page 13
To completely detach the front section, remove the 4
large screws as shown above then unfold the front
section. Use a 10mm spanner to remove the 2 nuts
holding the metal support straps and lift the straps off
the bolts. Replace the nuts to retain the fibre washers.
Carefully unfold the front section to the fully open
position.
Disconnect the 3-phase cable to the front section from the input
terminal block on the rear section and un-bolt the earth
connection. Cut the cable tie that secures the 3-phase input
cable
For hardwired output versions only
10-Amp output versions
Un-plug the load connector plugs from the
load terminal blocks on the rear section.
These connections are tight and will need to
be prised out.
25-Amp output versions
Remove the load terminal block by undoing the nuts that secure the terminal block to the rear
section.
The front section can now be removed from the rear section by sliding it sideways off the split hinges.
The rear section has provisions for mounting to walls and other
upright structures such as uni-strut. Mounting brackets for
P1000
Uni-Strut
are available from LSC.
Uni-Strut brackets
Remove
10mm nut
Support
strap
Disconnect 3-phase
power and earth that
feeds the front section
Cut cable tie
Load terminal
blocks
Load connector plugs
shown partially
disconnected