Chapter 5. Detailed specification of Communication Profile Specific objects
64
Description
Number of the occurred errors
Access
RW (Read/ Write)
Data
Read Number of the current emergency errors
Write Enter “0” to rest all the emergencies
Sub-index
0x01
Description
Information on the last emergency
Access
RO
Data
The value of Error code (Refer to Error code table of
6.1.2.1)
Sub-index
0x02~0x08
Description
Information on the last emergency
Access
RO
Data
The value of Error code (Refer to Error code table of
6.1.2.1)
5.4 COB-ID SYNC Message
The SDO for reading and writing the information on the CAN ID of the device
that sends the SYNC Message.
The Bit format is as follows;
The iG5A CANopen Option only receives and does not generate SYNC, and
supports Standard ID only. Therefore, both the gen and frame must be 0.
Index
0x1005
Data type
UNSIGNED32
Sub-index
0x00
Access
RW
Data
Read COB-ID of the current SYNC setting
Write Set up the COB-ID of SYNC