![LS Industrial Systems iG5A Series Скачать руководство пользователя страница 86](http://html1.mh-extra.com/html/ls-industrial-systems/ig5a-series/ig5a-series_manual_1943816086.webp)
Chapter 6. Profile
74
▶
vl velocity demand (Object: 0x6043)
Index
: 0x6042
Function:
Current target velocity
Unit
: rpm
Basic format
: 0
Setting range
: -30000 ~ 30000
(- value represents inverse run, + represents normal run, the range varies
by the parameter setting.)
▶
vl velocity actual value (Object: 0x6044)
Index
: 0x6044
Function
: Current run velocity
Unit
: rpm
Basic format
: 0
Setting range
: -30000 ~ 30000
(- value represents inverse run, + represents normal run, the range varies
by the parameter setting.)