Calibration File
The calibration file, transform.xml, contains settings that defines the transformation from sensor
coordinates to system coordinates, encoder resolution and distance (in direction of travel) between main
and buddy sensor (used for staggered orientation)
User can use Read and Write File command to modify the calibration file.
Calibration Example:
<?xml version="1.0" ?>
<SysCal version="1">
<YDomain>0</YDomain>
<YResolution>0</YResolution>
<Entries>
<Entry id="0">
<X>-2.3650924829</X>
<Y>0</Y>
<Z>123.4966803469</Z>
<Angle>5.7478302588</Angle>
<Orientation>0</Orientation>
</Entry>
<Entry id="1">
<X>0</X>
<Y>0</Y>
<Z>123.4966803469</Z>
<Angle>0</Angle>
<Orientation>0</Orientation>
</Entry>
</Entries>
</SysCal>