54
C5 dIG s
erIes
f
ault
C
odes
& d
IaGnostICs
Connect Touchpad: Digital Inverter System Self Diagnostics
Livezi systems are able to detect a number of problems and display a fault message to aid in
troubleshooting.
Fault D1 - 3 Phase error Digital Outdoor
Line 1 =
Fault D1:
Line 2 scrolls one of the following:
3 Phase, L2 & L3 lost
3 Phase, L2 lost
3 Phase, L3 lost
3 Phase, rotate L2 & L3
Fault D2 - Coil Sensor Error (sensor nominated)
Line 1 =
Fault D2:
Line 2 scrolls one of the following:
Outdoor coil sensor o
p
en circuit
Outdoor coil sensor short circuit
Indoor coil sensor o
p
en circuit
Indoor coil sensor short circuit
Fault D3 - High Pressure or Low pressure Fault
Line 2 scrolls one of the following:
HP com
p
ressor safet
y
LP com
p
ressor safet
y
HP/LP com
p
ressor safet
y
Fault D4 - Interconnect Indoor > Outdoor
Line 1 =
Fault 4:
Line 2 scrolls one of the following:
AHU and Condenser Interconnect
Fault D5 - Contact Manufacturer
Line 1 =
Fault 5:
Line 2 scrolls
Contact Manufacturer
Fault D6 - Contact Manufacturer
Line 1 =
Fault 6:
Line 2 scrolls
Contact Manufacturer
Fault D7 - Zoning to Indoor Board Communications Lost
Line 1 =
Fault D7:
Line 2 scrolls
AHU and Zoning interconnect
Fault D8 - Contact Manufacturer
Line 1 =
Contact Manufacturer
Содержание Bravo H-DIG-18
Страница 9: ...9 2 2 2 VAV Series Drawings H VAV 7...
Страница 10: ...10 H VAV 11...
Страница 11: ...11 H VAV 15...
Страница 12: ...12 H VAV 18...
Страница 13: ...13 1314 1550 81 487 60 410 601 60 300 H VAV 22 H VAV 26...
Страница 14: ...14 2 2 2 Radical Flow Series Drawings H RAD 22 H RAD 26 H RAD 15 H RAD 18...
Страница 21: ...21 Indoor Electrical Connection Diagram H VAV 22 26...
Страница 22: ...22 Indoor Electrical Connection Diagram H RAD 18 22 26 Indoor Electrical Connection Diagram H RAD 11 15 18...
Страница 56: ...56 Livezi Phone 1300 306 125 Fax 07 3870 8270 Web www livezi com au Email info livezi com au...