25
3.1.2 C
entral
C
ontroller
C
ommIssIonInG
s
teps
The following tables detail the the configuration DIP switches for the system control modules.
Factory default settings are OFF.
To facilitate the commissioning process, each control modules DIP switches should be set to
the positions indicated by the shading.
NOTE: The outdoor unit DIP switches 1 and 4 must be returned to the OFF position at the end
of the commissioning process for normal operation.
Outdoor Unit DIP switches
DIP switch #
Function
OFF
On
1
Compressor delay
255 ± 5 seconds
15 ± 5
seconDs
2
Indoor Coil Target Temp
7 - 9
°C
5 - 7 °C
3
N/A
F
actory
D
eFault
-
4
Compressor Lock
Compressor Runs
c
ompressor
will
not
r
un
nOTE: When selecting Indoor Coil Target Temperature range of 5 - 7 °C ensure duct insulation is
sufficient to maintain external duct temperature above dew point
Indoor Unit DIP switches
DIP switch #
Function
OFF
On
1
Minimum Fan Speed
Reduction
%
n
o
a
Djustment
1
2
n
o
a
Djustment
2
3
n
o
a
Djustment
4
4
No Adjustment
8
5
No Adjustment
16
6
Maximum Fan Speed
Reduction
%
n
o
a
Djustment
4
7
n
o
a
Djustment
8
8
n
o
a
Djustment
16
Before connecting power
Ensure all electrical and control connections have been made as per the relevant connection
diagram in Appendix A. If the wall controller sensor is to be the system sensor, ensure DIP
switch 1 on the wall controller is on.
Initial Power On
When power is applied to the system, the start-up routine will check communication to each
control module. Check the main modules for red fault LEDs.
Maximum Fan Speed Reduction
Maximum Fan Speed should only be reduced if register noise at all outlets is above an
acceptable level. For instances where register noise is not acceptable at one or two registers,
use the air balance to rectify.
To reduce the maximum fan speed, DIP switches 6, 7 and 8 on the Indoor Unit Module can be
switched to the ON position.
Содержание Bravo H-DIG-18
Страница 9: ...9 2 2 2 VAV Series Drawings H VAV 7...
Страница 10: ...10 H VAV 11...
Страница 11: ...11 H VAV 15...
Страница 12: ...12 H VAV 18...
Страница 13: ...13 1314 1550 81 487 60 410 601 60 300 H VAV 22 H VAV 26...
Страница 14: ...14 2 2 2 Radical Flow Series Drawings H RAD 22 H RAD 26 H RAD 15 H RAD 18...
Страница 21: ...21 Indoor Electrical Connection Diagram H VAV 22 26...
Страница 22: ...22 Indoor Electrical Connection Diagram H RAD 18 22 26 Indoor Electrical Connection Diagram H RAD 11 15 18...
Страница 56: ...56 Livezi Phone 1300 306 125 Fax 07 3870 8270 Web www livezi com au Email info livezi com au...