MAIN 1200 STARTUP SCREEN (General overview)
Trailer Information Panel:
VIN Number = (Required) VIN of Trailer or Dolly to be tested
Operator = The current user of this test system
Customer = Whoever is purchasing the vehicle (or the owner of the vehicle)
Order Number = As needed, for tracking of test data for specific customers
Configuration = Type of Trailer / Dolly being tested.
1. Trailers NOT designed to tow another vehicle
2. Trailers designed to tow another vehicle
3. Trucks and busses NOT designed to tow another vehicle
4. Trucks, Tractors and single units designed to tow another vehicle
5. Trailer conversion dolly
Tests to Run section:
1. Electrical 2. Air Leak 3. 121 Timing 4. Differential
NOTE: The Air Leak Test must be also selected and run immediately before the 121 Timing or the Differential test.
After selection(s) made, click “START” to initiate. Tests will run sequentially until they all pass or a failure is
encountered.
Test Status section:
Displays the results of each test as it happens. If a failure is encountered, all testing will stop and the failure will be
displayed. When not running air tests, you can also activate individual manual electrical tests here.
Header
Bar
Vehicle
and
customer
info
Select
desired
tests to
run
Air
Pressures
available
Software
version
of this
GUI.
Header Bar section:
Dropdown menus under each item. (The ‘HUB’ icon shows the battery charge which is left
in the Hub. The Radio Signal Strength with the Hub is shown next to the battery icon.)
Lite-Check CERTIFIER 1200 Operations Manual
WHAT YOU WILL SEE ON THE 1200 CERTIFIER GUI SCREENS
This entire side is the
Trailer Information Panel
This entire side is the
Test Status
section
“Start” button
Voltage and
current status
Activate
specific
tests