This is the end of the 121 Timing Self-Test, without using a trailer or dolly.
To adjust the
SET time.
To adjust the
RELEASE time.
121 Timing Self-Test, without a trailer or dolly (continued):
The SET time should read 350 - 355 milliseconds and the RELEASE time should read
read 700 - 705 milliseconds.
·
To increase the
SET
time, turn the valve on the FRONT of the Air Manifold
clockwise.
·
To decrease the
SET
time, turn the valve on the FRONT of the Air Manifold
counter-clockwise.
·
To increase the
RELEASE
time, turn the valve on the RIGHT SIDE of the Air
Manifold clockwise using a large screwdriver.
·
To decrease the
RELEASE
time, turn the valve on the RIGHT SIDE of the Air
Manifold counter-clockwise using a large screwdriver.