NORMAL POWER-UP PROCEDURE
1. Normal Power-up Procedure:
►
If you will be adding a sensor to the test configuration, be sure the tester and Hub are
turned off prior to doing so.
►
If you will be testing a vehicle designed to tow other vehicles, if it’s not already attached,
you will need to attach a sensor to the quick disconnect on the Differential Kit, and attach the
other end of this cable to the “Sensor Port” on the right side of the tester.
NOTE: If you will
never test a vehicle used to tow another vehicle, skip this bullet entirely.
►
If not already powered up, turn the Hub on by using its red button.
►
Supply 110 VAC to the Tester and turn on the Tester using the switch on the left side.
►
Connect the air source. Minimum pressure for the air source is 110 psi at 10 SCFM.
►
Wait about 30 seconds to allow the air tank inside the Tester to pressurize and stabilize.
►
At this time, the “Main 1200 Startup Screen” should be displayed. (A screenshot is shown
below.) Near the bottom of the left side of this view, there is an
“Input”
air pressure reading.
►
Adjust the regulator on the outside of the left side of the 1200 Tester so the input pressure
displayed on this screen is between 100 and 105 psi. We recommend 102 psi.
►
The CERTIFIER 1200 Tester is now ready for use.